-35%
, , ,

Schneider A9N18468 | Miniature circuit-breaker, Acti9 C120H, 3P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)

Schneider Electric
Availability:

Out of stock


 Schneider A9N18468 | Miniature circuit-breaker, Acti9 C120H, 3P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)

4.921,05 EGP 7.513,06 EGP

Out of stock

Compare

 Schneider A9N18468 | Miniature circuit-breaker, Acti9 C120H, 3P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)

Technical Specifications A9N18468

  • Product Reference: A9N18468

  • Product Family: Acti9 C120H

  • Type: Miniature Circuit Breaker (MCB)

  • Number of Poles: 3P (Three Pole)

  • Rated Current (In): 80 Amperes

  • Tripping Curve: C Curve (moderate inrush current handling)

  • Breaking Capacity (IEC 60898-1): 15,000 A

  • Breaking Capacity (IEC 60947-2): 15 kA

  • Rated Operational Voltage: 400 V AC

  • Insulation Voltage (Ui): 500 V

  • Frequency: 50/60 Hz

  • Mounting: DIN rail

  • Protection Degree: IP20 (in modular enclosure)

  • Standards: IEC 60898-1, IEC 60947-2

Key Features:

  • High Breaking Capacity (15 kA)
    Delivers reliable protection in circuits where high short-circuit currents are possible.

  • Three-Phase Protection
    Ideal for balanced three-phase loads, ensuring full disconnection and coordinated trip performance.

  • C Curve Trip Characteristic
    Provides precise protection for circuits with moderate inrush currents, such as motors, transformers, and lighting systems.

  • Thermal and Magnetic Protection
    Built-in dual trip mechanisms safeguard against both overload and short-circuit faults.

  • Compact Modular Design
    Saves panel space while maintaining robust electrical performance.

  • Fast DIN Rail Mounting
    Supports easy and secure installation in standard electrical distribution panels.

  • Reliable Performance
    Engineered by Schneider Electric for consistent operation in demanding environments.

Applications:

  • Industrial Electrical Panels
    Protects motors, HVAC systems, and automated equipment in factory settings.

  • Commercial Buildings
    Used in distribution boards for lighting, outlets, and machinery.

  • Three-Phase Distribution Circuits
    Essential for safeguarding multi-phase power distribution systems.

  • Critical Infrastructure
    Ideal for hospitals, data centers, and other facilities that demand uninterrupted protection.

  • Heavy-Load Circuits
    Suitable for applications with moderate surge loads and continuous high current demands.

Main Document

Data Sheet : Download

Based on 0 reviews

0.0 overall
0
0
0
0
0

Be the first to review “Schneider A9N18468 | Miniature circuit-breaker, Acti9 C120H, 3P, 80 A, C curve, 15000 A (IEC 60898-1), 15 kA (IEC 60947-2)”

There are no reviews yet.

SHOPPING CART

close

Select at least 2 products
to compare